site map

Vacuum Pumps, Venturis, Vacuum Generators, EjectorsVacuum Pumps and Vacuum Generators
Multi-Stage Air Powered Vacuum Pumps with External Exhaust Silencer MSP Series
MSP400-S Vacuum Station

View Printer-Friendly PDF Page


Usage
ANVER's MSP400-S Multi-Stage Pneumatically-Driven Vacuum Station operates on the venturi principle. The MSP400-S is ideally designed for applications requiring high flows at moderate vacuum levels. The MSP400-S Vacuum Station provides vacuum levels down to 27” Hg, and flows to 148 SCFM. Its efficient operation makes the MSP400-S suitable for a wide range of applications, particularly in the packaging and material handling industries, as well as in the industrial automation and laboratory environments.

Features:
• A good choice for high flow at moderate vacuum levels.
• Minimum space requirements.
• Economical proven design.
• Lightweight, precise aluminum construction with brass nozzles.
• Equipped with exhaust muffler to reduce noise level.
• Low Maintenance, no internal moving parts.
• Generates no heat.
• Well Suited for use in Explosion Proof Environments.


Dimensional Specifications for MSP400-S Vacuum Station

Request
for Quote

Model
Number

MSP400-S

Specifications:
Compressed Air Required: 50 Micron, dry, filtered, non-lubricated
Operating Temperature: -14 to +176°F (-10 to +80°C)
Optimum Operating Pressure: 87 psi (6 bar)
Minimum of 1/2" air supply line required

ANVER
Model Number

Max Vacuum
in. Hg
(mm Hg)

Vacuum Flow
SCFM
(L/min.)

Air Consumption
SCFM
(L/min.)

Input Pressure
psi
(bar)
Unit Weight
lb
(kg)
Max Vacuum
Level @ Sea Level
in. Hg
(mbar)

MSP400-S

27
(690)

148.26
(4200)

49.42
(1400)

87
(6)
19
(8.6)
27
(914)

Air consumption and vacuum flow at various vacuum levels (-Hg) at 87 psi.

Model
Number
Vacuum Flow at Vacuum Level
SCFM
(L/min.)
0 Hg 3 Hg 6 Hg 9 Hg 12 Hg 15 Hg 18 Hg 21 Hg 24 Hg
MSP400-S 148.26
(4200)
105.90
(3000)
69.19
(1960)
36.71
(1040)
25.42
(720)
20.47
(580)
15.18
(430)
9.88
(280)
5.93
(168)

The "G" thread is a straight pipe thread also known as BSPP, NPS or "G", commonly used in Europe, Asia and most of the world.

 


ANVER Corp.,  36 Parmenter Rd,  Hudson, MA  01749  USA  -  Tel: 800-654-3500  -  +1-978-568-0221  -  Fax: +1-978-568-1570

Home: www.anver.com    email:

Copyright © ANVER Corp. 2012

Terms of use