Vacuum
System Components
Vacuum Sensor and Vacuum
/ Pressure Switch
A-PSE5 Series Digital Switch
View Printer-Friendly PDF Page
|


|
The A-PSE5 Series Digital Switch
offers independent use of vacuum / pressure switch head. Data can be
controlled by taking the analog voltage output (1 to 5V) from the sensor
head and feeding it to a digital panel meter. Mounting the detachable head
close to the detecting section minimizes piping and enables response time
of 1ms, the fastest in the industry, as well as greatly decreasing tact
time delay. In addition, the ultra-small and light-weight design of the
head means it can easily be mounted on moving sections. Features:
-
1ms
Response - Fastest in the Industry
-
Detachable
Head
-
Switch
Head with operation Indicator
-
Convenient
Intermediate Cable
-
Easy
Mounting, Mobile Pressure Port
-
Two
Types of Output, NPN and PNP - for Worldwide Use
|
|
ANVER
Part
Number |
Description |
|
|
A-PSE511-01
|
Vacuum / Pressure Switch Head |
|
|
A-PSE5
|
Vacuum / Pressure Switch
Controller |
|
|
A-PS5-CC3
|
Standard Intermediate Cable: 3m |
Specifications
for A-PSE511-01 Vacuum / Pressure Switch Head:
| Vacuum Pressure |
-101kPa type |
| Rated
Pressure Range (Note 1) |
0
to -101.3kPa |
| Pressure
Withstandability |
500kPa |
| Applicable
Fluid |
Non-Corrosive
Gas |
| Supply Voltage |
12 to 24 DC +10% to
-15% Ripple P-P 10% or less |
| Current
Consumption |
15mA
or less (operation indicator off) / 17mA or less (operation indicator on) |
| Analog
Voltage Output |
Output Voltage: |
1 to 5V (over pressure range) |
| Zero
Point: |
within
1V±2%F.S. (vacuum/positive pressure type)
within 3V±3%F.S. (compound pressure type) |
| Span: |
within 4V±3.5%F.S. |
| Linearity: |
within ±1%F.S. |
| Output Impedance: |
1kΩ approx. |
|
Environmental
Resistance |
Pollution
Degree |
3
(Industrial Environment) |
| Protection |
IP40
(IEC) |
| Ambient
Temperature |
0
to +50°C (No Dew Condensation), Storage: -10 to +60°C |
| Ambient
Humidity |
35
to 85% RH, Storage: 35 to 85% RH |
| EMC |
Emission:
EN50081-2, Immunity: EN50082-2 |
| Voltage
Withstandability |
1,000V
AC for one min. between all supply terminals connected together and
enclosure |
| Insulation
Resistance |
50MΩ,
or more, with 500V DC megger |
| Vibration
Resistance |
10
to 500Hz frequency, 3mm amplitude, or 5G in X, Y and Z directions for two
hours each |
| Shock
Resistance |
1,000m/s2
Acceleration in X, Y and Z direction for three times each |
| Operation indicator |
Orange LED light |
| Temperature
Characteristics |
Over
Ambient Temperature Range +10 to +40°C: within ±1%F.S. of detected
pressure at +25°C |
| Over
Ambient Temperature Range 0 to +50°C: within ±3%F.S. of detected
pressure at +25°C |
| Voltage
Characteristics |
Within ±0.5%F.S. for
±10% fluctuation of the supply voltage |
| Pressure
Port |
A-PSE11-01
NPT 1/8 male thread / 10-32UNF female thread |
| Material |
Enclosure: PBT,
Pressure Port: Brass (nickel plated) |
| Connecting
Method |
Connector |
| Cable |
0.2mm2
4-core connector attached oil resistant cabtyre cable, 100mm long |
| Cable
Extension |
Extension
up to total 10m is possible with 0.3mm2, or more, cable |
| Weight |
10g approx. |
Specifications
for A-PSE5 Vacuum / Pressure Switch Controller:
| PNP
Output Type |
PSE5 |
| Rated
Pressure Range (Note 1) |
Vacuum
Pressure: 0 to -101.3kPa |
| Set
Pressure Range (Note 1) |
Vacuum Pressure:
101.3kPa (1.033 to -1.033kgf/cm2, 14.70 to -14.70psi, 1.013 to
-101.3bar, 760 to -760mmHg, 29.9 to -29.9inHg) |
| Supply
Voltage/Current Consumption |
12 to 24 DC +10% to
-15% Ripple P-P 10% or less / 60mA or less (not including pressure sensor
head) |
| Sensor
Supply Voltage |
Same as Supply
Voltage |
Comparative
Output
(Comparative Output 1
Comparative Output 2) |
PNP
Open-Collector Transistor (2 outputs)
· Maximum source current: 100mA
· Applied Voltage: Same as supply voltage
(between comparative output and +V)
· Residual Voltage: 2V or less (at 100mA source current) |
| Utilization
Category |
DC-12 or DC-13 |
| Output
Operation |
NO/NC,
selectable by key operation |
| Output
Modes |
Equipped with 4
types of modes: hysteresis mode, window comparator mode, leak test mode,
forced output mode (selectable by key operation) |
| Hysteresis |
1
digit
(however, set response time is +2ms when auto-reference/remote
zero-adjustment input is applied) |
| Repeatability |
Vacuum/positive
pressure type sensor head: within ±0.2%F.S. ±1 digit (±3 digits) |
| Response
Time |
1ms,
16ms, 128ms, 512ms, or less, selectable by key operation (however, set
response time is ±2ms when auto-reference/remote zero-adjustment input is
applied) |
| Short-Circuit
Protection |
Incorporated |
| Input |
Pressure
Sensor Head Input |
Input
Voltage Range: 1 to 5V DC (over rated pressure range) |
| Auto-Reference/Remote
Zero-Adjustment Input |
Input
Condition: PNP non-contact input [operates in High (rise) state]
Signal Condition: High... 5 to 30V, Low... 0.4V or less, or open, High
Level Input Time... 2ms or more |
| Analog
Voltage Output |
· Output
Voltage: 1 to 5V DC (over rated pressure range)
· Zero Point: within 1V ±2.5%F.S. (vacuum/positive pressure type)
within 3V ±3.5%F.S. (compound pressure)
· Span: within 4V ±4%F.S.
· Linearity: within ±1%F.S.
· Output Impedance: 1kΩ approx. |
| Display |
3½
digit LCD Display (with red and green backlight) (Display refresh cycle:
256ms, 512ms, or 1024ms selectable by key operation) |
| Displayable
Pressure Range |
Vacuum Pressure: 5.1
to -101.3kPa (0.052 to -1.033kgf/cm2, 0.74 to - 14.70psi, 0.05
to -1013bar, 38 to -760mmHg, 1.5 to -29.9inHg) |
| Operation
Display |
LCD
Segment is red when comparative output is ON, and green when it is OFF
(output is selected via supplementary settings) |
| Analog
Bar Display |
Bar Display in steps
of 14% F.S. approx. |
| Operation
Indicator |
Orange
LED (lights up when comparative output is ON), green LED (lights up when
comparative output 2 is ON) |
|
Environmental
Resistance |
Pollution Degree |
3 (Industrial
Environment) |
| Protection |
IP40
(IEC) |
| Ambient Temperature |
0 to +50°C (No dew
condensation), Storage: -10 to +60°C |
| Ambient
Humidity |
35
to 85% RH, Storage: 35 to 85% RH |
| EMC |
Emission: EN50081-2,
Immunity: EN50082-2 |
| Voltage
Withstandability |
1,000V
AC for one min. between all supply terminals connected together and
enclosure |
| Insulation
Resistance |
50MΩ, or more,
with 500V DC megger between all supply terminals connected together and
enclosure |
| Vibration
Resistance |
10
to 150Hz frequency, 0.75mm amplitude, or 5G in X, Y and Z directions for
two hours each |
| Shock Resistance |
100m/s2 Acceleration
in X, Y and Z directions for three times each |
| Temperature
Characteristics |
Over
Ambient Temperature Range 0 to +50°C: within ±0.5%F.S. of detected
pressure at +25°C (not including pressure sensor head) |
| Material |
Front Case: ABS, LCD
display section: PET, Rear cse: PBT |
| Connecting
Method |
Connector |
| Suitable
Cable |
Conductor
Cross-Section Area (Note 2) |
0.16 to 32mm2 (AWG #25
to #22) |
| Lead
Wire Diameter |
ø1.2
to ø1.8mm |
| Wire Material |
Tin plated, soft,
twisted, copper wire |
| Cable
Extension |
Extension
up to total 100m is possible with 0.3mm2, or more, cable |
| Weight |
20g approx. |
Note
1: The rated pressure range indicates the range for full product performance.
Note 2: If the wiring is longer than 2m, use a cable with a diameter of 0.3mm2
or more.


|