site map

Vacuum Pumps, Venturis, Vacuum Generators, EjectorsVacuum Pumps and Vacuum Generators
Multi-Stage Air Powered Vacuum Pumps with External Exhaust Silencer MSP Series
Model No. MSP100

PDF for Miniature Vacuum Pumps View Printer-Friendly PDF Page

ANVER MSP100

Dimensional Specifications for MSP100

Schematic of Multi-stage Ejector Vacuum Pump
Request
for Quote

Model
Number

G
BSPP
H
in.
(mm)
I
in.
(mm)

MSP100 3/8G 1.65
(42)
2.63
(67)

 

ANVER
Model Number

Equivalent P-Series
Pump Number

Max Vacuum
in. Hg
(mm Hg)

Vacuum Flow
SCFM
(L/min.)

Air Consumption
SCFM
(L/min.)

MSP100

MLD100 (M100)

27
(690)

31.70
(900)

13.41
(380)

Air consumption and vacuum flow at different vacuum levels (-Hg) at 87 psi.

Model
Number
Air
Consumption
SCFM
(L/min.)
Vacuum Flow at Vacuum Level
SCFM
(L/min.)
0 Hg 3 Hg 6 Hg 9 Hg 12 Hg 15 Hg 18 Hg 21 Hg 24 Hg
MSP100 13.41
(380)
31.77
(900)
28.1
(796)
15.18
(430)
9.74
(276)
7.06
(200)
5.51
(156)
4.24
(120)
2.97
(84)
1.62
(46)
 The "G" thread is also known as BSPP, commonly used world-wide for Vacuum Applications.

 


ANVER Corp.,  36 Parmenter Rd,  Hudson, MA  01749  USA  -  Tel: 800-654-3500  -  +1-978-568-0221  -  Fax: +1-978-568-1570

Home: www.anver.com    email:

Copyright © ANVER Corp. 2012

Terms of use