site map

ANVER Vacuum Pumps, Vacuum GeneratorsVacuum Pumps and Vacuum Generators
Single-Stage Vacuum Pumps
JB25-X ("G" BSP Version)
 

Electrical Schematic of JB Series Vacuum Generator

Dimensional Specifications and Diagram of JB Series Vacuum Generators

Specifications:

Compressed Air:

50 Micron, Filtered, Non-lubricated

Operating Temperature:

-10 to 80°C (14 to 176°F)

Optimum Operating
 Pressure:

5 bar  (72.5 psi)

Valve Material:  Anodized Aluminum, Brass Nozzle
Part No. Nozzle
Size
A 
Air Inlet
B 
Vacuum
Port
C 
Optional
Gauge
Port
D 
in.
(mm)
L1
 in.
(mm)
L2 
in.
 (mm)
Air
Consumption

scfm
(ml/min.)
Vacuum
Flow

scfm
(ml/min.)
Vacuum
Level

in Hg
(-mmHg)

JB25-X 25 G 1/4" G 1/2" G 1/8" 1.25
(32)
5.22
(132.2)
2.95
(75)
9.20
(260)
7.06
(200)
27
(690)

 


ANVER Corp.,  36 Parmenter Rd,  Hudson, MA  01749  USA  -  Tel: 800-654-3500  -  +1-978-568-0221  -  Fax: +1-978-568-1570