Vacuum Pumps, Vacuum Generators, Vacuum Stations, Vacuum BlowersVacuum Pumps and Vacuum Generators
Regenerative Vacuum Stations and Vacuum Pumps
VB Series

Vacuum Pumps and Vacuum Pumps with Motors for Harsh EnvironmentsANVER Best Prices Guarantee

ANVER offers select models of high efficiency vacuum pumps specially designed for ANVER, and used as part of its vacuum lifting systems. These revolutionary regenerative pumps offer a compact, reliable source of quiet, vibration-free vacuum. ANVER's quality vacuum pumps are made from tough, high-strength materials for long life, and are lightweight and virtually maintenance free. Their highly efficient, state-of-the-art design has rendered the older designs of conventional side-channel blowers obsolete. Vacuum pumps are available in capacities of up to 480+ cfm flow and 18 in. Hg vacuum. Powered by high quality motors, they are more energy efficient, require less horsepower to operate than competitive models, and are offered in a variety of sizes to match your vacuum lifting requirements.

ANVER's high efficiency vacuum pumps are also known as Regenerative Blowers, Ring Compressors, Vortex Blowers, and Side-Channel Blowers by other manufacturers. The difference with these pumps is the precision and quality of parts used, allowing vacuum level and flow to be achieved with lower noise levels. Most of these pumps can be used to create either vacuum or pressure flow. The pumps ANVER offers are the highest quality on the market, with surprisingly low prices in relation to their performance. These pumps are available as both complete vacuum stations (which feature heavy duty mufflers and all appropriate connection fittings), and as replacement units. NOTE: Optional vacuum or pressure relief valves are also recommended.

 
Voltage Available Phase Cycle
Dual Voltage: 230/460 or 220/440
Single Voltage: 575V
3 phase 60
Single Voltage: 208/380V 3 phase 50

* Note: When operated at 50 Hz, pump capacity is decreased by 1/6th (16.7%). Consult Factory for more information and other available non-standard configurations.
 

Standard Regenerative Direct-Drive Vacuum Pumps and Vacuum Stations
Note: Vacuum Stations include a large muffler and fittings

Product
Photo
(Click to Enlarge)

Complete
Station
Part Number

HP
(KW)

SCFM
(l/min.)

Max.
Vacuum
in. Hg
(mm Hg)

Product
Photo
(Click to Enlarge)

Pump
Part
Number

Sound
Enclosure

Shipping
Wt.
lb
(kg)

Vacuum
Relief
Valves
Rec'd
Cord
Strain
Relief
VB3HF-S

VB3HF-S

3.4
(2.53)

142
(4021)

8
(203)

VB3HF

VB3HF

SDE-3

53
(23.5)

VB4HF-S

VB4HF-S

4.8
(3.58)

220
(6230)

12
(305)

VB9HV

VB4HF

SDE-4

75
(33.3)

VB7HV-S

VB7HV-S

3.42
(2.55)

90
(2547)

18
(457)

VB4HF

VB7HV

SDE-7

94
(41.70)

VB8HF-S

VB8HF-S

8.5
(6.34)

325
(9204)

12
(305)

VB8HF

SDE-8

277
(122.89)

VB9HV-S

VB9HV-S

7.5
(5.59)

120
(3398)

18
(457)

VB4HF

VB9HV

SDE-9

112
(49.69)

VB9HV-S

VB11HV-S

8.9
(6.60)

180
(5097)

18
(457)

VB9HV-S

VB11HV

Info to
Come

190
(86)

Direct-Drive Vacuum Pumps and Vacuum Stations

Regenerative Vacuum Stations
Note: Vacuum Stations include a large muffler and connection fittings
Click on Classification for Definition

Station Part
Number

HP

Class1/
Division1/
Group D

Class 1/
Division 1/
Group C&D

Class 2/
Division 1/
Group F&G

VB4HF-S 4.8 VB4HF-S-X11D
VB4HF-S-X11CD
VB4HF-S-X21FG
VB7HV-S 5.0 VB7HV-S-X11D
VB7HV-S-X11CD
VB7HV-S-X21FG

VB8HF-S

8.5 VB8HF-S-X11D
VB8HF-S-X11CD
VB8HF-S-X21FG
VB9HV-S 7.5 VB9HV-S-X11D
VB9HV-S-X11CD
VB9HV-S-X21FG
VB11HV-S 8.8 VB11HV-S-X11D
VB11HV-S-X11CD
VB11HV-S-X21FG

Regenerative Vacuum Pumps Only

Pump Part
Number

HP

Class 1/
Division 1/
Group D

Class 1/ 
Division 1/
Group C&D

Class 2/
Division 1/
Group F&G

VB4HF 4.8 VB4HF-X11D
VB4HF-X11CD
VB4HF-X21FG
VB7HV 5.0 VB7HV-X11D
VB7HV-X11CD
VB7HV-X21FG

VB8HF

8.5 VB8HF-X11D
VB8HF-X11CD
VB8HF-X21FG
VB9HV 7.5 VB9HV-X11D
VB9HV-X11CD
VB9HV-X21FG
VB11HV 8.8 VB11HV-X11D
VB11HV-X11CD
VB11HV-X21FG
Sound Enclosures
Sound Enclosures for Vacuum Pumps and Vacuum Stations

ANVER Vacuum Tube Lifting Systems use vacuum pumps and vacuum stations that already meet OSHA guidelines for noise levels. For added comfort or for use where low noise is desired as a premium, sound deadening enclosures are available in most common sizes. As a general rule, sound enclosures reduce sound by 5-7 dB for vacuum pumps operating in the 68-76 dB range. Although this may seem vague, it is true since sound readings can vary by this amount simply by changing the location where you are standing when you are taking the sound readings. ANVER sound deadening enclosures are built from durable, melt-resistant, industrial-quality plastic. They have a steel plate base and are fully lined with sound deadening foam. It is best to obtain these enclosures when you purchase the vacuum station as they require special plumbing: the intake and exhaust pipes need to be lengthened to port correctly.

The following enclosure sizes are available from stock. When sold separately, extra pipe fittings, though a small amount, must be added. Check with the factory for details.

Sound Enclosure Dimensional Diagram

Sound Enclosure for Vacuum Station

Click to
View Photo

Model
No.

Fits
Vacuum
Station
Complete
Station
Part Number

A
in.
(mm)

B
in.
(mm)

C
in.
(mm)

D
in.
(mm)
E
in.
(mm)
SDE-3
VB3HF-S

VB3HF-S

33.00
(838)

24.00
(610)

21.50
(545)

N/A N/A
SDE-4
VB4HF-S

VB4HF-S

33.00
(838)

24.00
(610)

21.50
(545)

35.00
(889)
11.40
(290)
SDE-7
VB7HV-S

VB7HV-S

33.00
(838)

24.00
(610)

21.50
(545)

35.00
(889)
12.92
(328)
SDE-8
VB8HF-S

VB8HF-S

29.25
(743)

30.00
(762)

38.75
(984)

31.25
(794)
19.00
(483)
SDE-9
VB9HV-S

VB9HV-S

33.00
(838)

24.00
(610)

21.50
(545)

35.00
(889)
14.64
(372)

Vacuum System Accessories
Heavy-Duty Quality Exhaust Mufflers

MU-VB112 on a VB-9 Vacuum Blower

These attractive, quality exhaust mufflers feature a rugged, heavy-duty construction. The top and bottom covers are cast aluminum with a metal perforated housing for heat resistance. The tie rods and nuts are zinc-plated steel. At an in-line pressure of 90 psi, these mufflers reduce the noise level by 17-22 decibels with little impairment of operating efficiency. They are supplied with NPT male connections.

Specifications:

Maximum Pressure:

125 psi

Maximum Temperature:

300° F (149° C)

Product Photo
(Click to
Enlarge)

Part No.

Thread NPT

Description

MU-VB2

MU-VB112

1-1/2"

Exhaust Muffler for Regenerative Vacuum Pumps

MU-VB112

MU-VB2

2"

Exhaust Muffler for Regenerative Vacuum Pumps


Vacuum Relief Valves

Drum Filters and Stands

 


ANVER Corp.,  36 Parmenter Rd,  Hudson, MA  01749  USA  -  Tel: 800-654-3500  -  +1-978-568-0221  -  Fax: +1-978-568-1570  

www.anver.com    ANVER Corp.

Copyright © ANVER Corp. 2014

Terms of Use | Site Map